PCW-CSRX Count Server For Direct-to-PC or Network Integration

Whatever you're counting or sensing (people, vehicles, temperature, humidity, proximity, doors, etc.) the Sensor Server processes and serves data received from up to 100 wireless PCW or XR series sensors equipped with an RF transmitter. Data can be automatically or manually downloaded from one or more local and remote Sensor Servers to one central PC using wired Ethernet (TCP/IP) or Serial (RS232) protocol. Historical data logs contain information to identify each location and each specific sensor within a location along with date and time stamped values. The Sensor Server can be programmed, controlled and queried using Server Manager Software or directly by using simple ASCII commands. The Sensor Server contains battery backed RAM so data is not lost with power outages. Server and sensor status with current values can be easily viewed in near real time. Your network is secure since wireless communication is only for data exchange between the Sensors and the Sensor Server so your network cannot be accessed wirelessly through the Sensor Server.

 

 

Data Receiver with integral IP addressable web server and browser based reporting.

The PCW Count Server is a 418 or 900 Mhz RF receiver with an integrated data Web server. It receives errorchecked data packets from wired or wireless sensors, processes the data, and makes the data available to be queried through dynamic HTML with any standard web browser. The Count Server gives reports of counts by half hour, hour, day, week and month. The Count Server also makes this same data available as text files downloadable through the browser using FTP. The Count Server can manage up to 16 sensors and can hold data for 3 months at 30-minute intervals, and for 1.5 years at day intervals. It is fully configurable, both locally (with the serial port) and remotely via Ethernet TCP/IP.

 

PCW-CSRX Features:

  • No additional software required

  • 418Mhz, or 900 MHz Receiver

  • 3.3” x 3.3” x 1.3” ABS enclosure

  • Communication: Ethernet (TCP/IP) or Serial (RS232)

  • Data Logger – Logs time stamped data of up to 16 Directional or 32
    Non-Directional People Counters for up to 1.5 years

  • Dynamic HTML browser based reporting

  • Data is downloadable to a text file via FTP

Click here for PDF Brochure

 

Ordering:

  • PCW-CSRX4 (Count Server with wireless 418 MHz data receiver)

  • PCW-CSRX9 (Count Server with wireless 900 MHz data receiver)

  • PC-CSRX485 (Count Server with wired RS485 serial data receiver

Typical Browser Report Screen

Typical configuration for multiple facilities